Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

04/02/21

Message Overview:


Message Name:

NO L-CDU-6 BUS INPUT

Message Code:

B3-648574

Associated CAS:

None

Reporting LRU: DME 1
System Description: 34-53-00
Schematic Diagram: 34-53-00
Wiring Diagram: 34-53-01
34-61-05



Message Description:

L-CDU-6 data absent at L-DME and not at least 3-of (L-IOC, L-NAV(ADF/VIR), L-VHF).

Possible Causes:

  • Distance Measuring Equipment 1 (DME) (A49)
  • Junction Box (JB3)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Junction Box JB3 AMM 24-63-09-000-802
Installation of the Junction Box JB3 AMM 24-63-09-400-802
Removal of the VHF Navigation Receiver AMM 34-51-01-000-801
Installation of the VHF Navigation Receiver AMM 34-51-01-400-801
Removal of the Distance Measuring Equipment (DME) Transceiver AMM 34-53-01-000-801
Installation of the Distance Measuring Equipment (DME) Transceiver AMM 34-53-01-400-801
Standard Practices - Replace Wiring SPM 20-12-00-02
Standard Practices - Repair Wiring SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Reset DME 1 (CB1-A2) circuit breaker.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  2. Swap DMEs.

    1. If system checks passes, do close out.
    2. If fault remains, continue with next step.

  3. Do a wiring check of the ARINC 429 data bus L-CDU-6 from DME 1 connector A49P1 to Junction Box 3 connector JB3DP1 or respective Test Point. Repair/replace as required.

    1. If system checks passes, do close out.
    2. If fault remains, continue with next step.

  4. Replace Junction Box 3.
  5. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.