04/07/21
Message Overview:
Message Description:
File Server Unit 1 has reported a configuration strapping error.
Possible Causes:
- File Server Unit 1 (FSU 1) (A221)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the File Server Unit (FSU) | AMM 46-21-01-000-801 |
| Installation of the File Server Unit (FSU) | AMM 46-21-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset L FILE SERVER (CB1-C6) circuit breaker.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check of the strapping at FSU 1 connector A221P1 (wires attached to SP447 and SP449). Replace/repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap FSUs. (If single FSU is installed, replace FSU 1).
- Do close out.