04/07/21
Message Overview:
Message Description:
File Server Unit 2 has reported a fan fault.
Possible Causes:
- File Server Unit 2 (FSU) Cooling Fan (A224)
- File Server Unit 2 (FSU 2) (A222)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Component Location | AMM 46-21-00-992-801 |
| Removal of the File Server Unit (FSU) | AMM 46-21-01-000-801 |
| Installation of the File Server Unit (FSU) | AMM 46-21-01-400-801 |
| Removal of the File Server Unit (FSU) Mounting Tray | AMM 46-21-03-000-801 |
| Installation of the File Server Unit (FSU) Mounting Tray | AMM 46-21-03-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset R FILE SERVER (CB2-C6) circuit breaker.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Confirm power and ground are available at FSU 2 Cooling Fan connector A224J/P2.
- If 28 VDC and ground are available, go to step 4.
- If 28 VDC and/or ground is not available, continue with next step.
- Do wiring check between FSU 2 Cooling Fan connector A224J/P2 and circuit breaker CB2-D6 R FILE SERVER. Replace/repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between FSU 2 connector A222P1 and FSU 2 Cooling Fan connector A224P/J2. Replace/repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap FSU Cooling fans.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap FSUs.
- Do close out.