Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

04/09/21

Message Overview:

Message Name:

BGDRHLK SHORTED

Message Code:

B3-007531

Associated CAS:

PROX SYS FAULT
(Advisory)

Reporting LRU: BGDRHLK SNSR
System Description: 32-60-00
52-70-00
Schematic Diagram: 32-61-00
52-71-00
Wiring Diagram: 32-61-09
32-61-12
52-71-05

Message Description:

Proximity-Sensor Electronic Unit (PSEU) detects an OPEN circuit within the Proximity Sensor PX46, Baggage Bay Door Closed or in the wiring to the proximity sensor or aircraft.

Possible Causes:

  • Proximity Sensor Electronic Unit (PSEU) (A9)
  • Baggage Door Handle Locked Proximity Sensor (PX46)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Proximity-Sensor Electronic Unit (PSEU) AMM 32-61-09-000-801
Installation of the Proximity-Sensor Electronic Unit (PSEU) AMM 32-61-09-400-801
Functional Test of the Proximity-Sensor Electronic Unit (PSEU) AMM 32-61-09-720-801
Operational Test of the Door Sensors AMM 52-71-00-710-801
Built-In Test of the Door Proximity-Sensors AMM 52-71-00-740-801
Removal of the Baggage-Door Locked Proximity-Sensor AMM 52-71-05-000-802
Installation of the Baggage-Door Locked Proximity-Sensor AMM 52-71-05-400-802
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Pull and reset the PSEU gear system breakers (CB1-C13, CB1-C14, CB2-C13,CB2-C14), recheck the system for the fault.
  2. Remove the PSEU from its rack and disconnect the connector SP114 from PX46. Verify the wiring check from the PX46 SP114 PIN A2 to ground and from PX46 SP114 PIN B2 to ground. The wires should be open to ground.
  3. If the wiring checks good, download and have field service review the PSEU NVM. Further troubleshooting will depend on results of the PSEU NVM.
  4. If the fault is still there, replace PX46 per the installation procedure, and then check the sensor out.
  5. If the fault is still there, replace the PSEU.
  6. Functional check the proximity sensor electronic unit.
  7. Do close out.