04/26/21
Message Overview:
Message Description:
The DC generator voltage output indication is showing 4 Volts on the electrical synoptic page when the engine(s) or APU are not operating.
Possible Causes:
- Generator
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-24-0195 - DC Generator - False 4-Volt Indication
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Main Generator | 24-31-05-000-801 |
| Installation of the Main Generator | 24-31-05-400-801 |
| Removal of the APU Generator | 24-31-09-000-801 |
| Installation of the APU Generator | 24-31-09-400-801 |
Troubleshooting Recommendations:
- Replaced the affected Generator.
NOTE:Swap with a known good one could also be done to confirm the failure. - Do close out.