04/26/21
Message Overview:
Message Description:
'NO DATA AVAILABLE' is displayed on MFD when the MDC data is invalid and the MFD is in Maintenance Mode.
Possible Causes:
- Left Multi-Function Display (MFD 1) (A28)
- Junction Box 2 (JB2)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB2 | AMM 24-63-05-000-803 |
| Installation of the Junction Box JB2 | AMM 24-63-05-400-803 |
| Removal of the Adaptive Flight-Display Unit | AMM 31-61-01-000-801 |
| Installation of the Adaptive Flight-Display Unit | AMM 31-61-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices -Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset L MFD Circuit Breaker CB1-C5. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Swap left MFD (A29) with right MFD (A28) Is the fault message still present?
- If YES, continue with next step.
- If NO, replace defective Adaptive Flight-Display Unit.
- Do wiring check between Junction Box 2 and left MFD (A29) for the following wires:
From To Result Conn. A29P2 - 92 Conn. JB2FP1 - F9 Conn. A29P2 - 93 Conn. JB2FP1 - G9 - If the check is satisfactory, continue with next step.
- If the check is not satisfactory, replace defective wiring.
- Replace Junction Box 2.
- Do close out.