01/26/21
Message Overview:
Message Description:
A loss of system inputs to the stall computer has caused the Stall Protection System to revert to a more conservative flap setting (flaps 30°).
Possible Causes:
- L Flap Position Sensor (MPE77)
- R Flap Position Sensor (MPE78)
- Flap Control Unit (FCU) (A124)
- Stall Protection Computer (SPC) (A178)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-27-0058 - Flap Control Unit - CAS Messages Reset procedure (20003 - 20999)
Forum Articles/Infoservice/Newsletter: None
If Flap Control Unit (FCU) PN:2257A0000-02 is installed, reset procedure included in AW300-27-0058 may clear the fault.
Quick Links:
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 |
| Removal of the Flap Control Unit (FCU) | AMM 27-51-05-000-801 |
| Installation of the Flap Control Unit (FCU) | AMM 27-51-05-400-801 |
| Electrical Rigging of the Flap System | AMM 27-52-00-820-801 |
| Removal of the Flap Position Sensor | AMM 27-52-17-000-802 |
| Installation of the Flap Position Sensor | AMM 27-52-17-400-802 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Check in the MDC in the current faults and fault history pages for problems related to Stall Protection System.
- If one of the faults below is reported by the MDC, proceed with their respective troubleshooting before.
- If none of the faults below is reported by the MDC, continue with next step.
- Check in the MDC in the current faults and fault history pages for problems related to FLAP CONTROL UNIT.
- If one of the faults below is reported by the MDC, proceed with their respective troubleshooting before.
- If none of the faults below is reported by the MDC, continue with next step.
- Reset the following circuit breakers.
STALL R PWR CB2-B10 STALL L PWR CB1-B10 FLAP R IND CB2-B12 FLAP L IND CB1-B13 FLAP CTRL CB1-B14 - Reset the FCU by pressing the FCU reset button on the MAINTENANCE TEST control-panel.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do the Electrical Rigging of the Flap system.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between FCU connectors A124AP1/ A124BP1 and Right Flap Position Sensor connectors A78AP1/A78BP1. Repair/replace as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between FCU connectors A124AP1/ A124BP1 and Left Flap Position Sensor connectors A77AP1/A77BP1. Repair/replace as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Check internal wiring integrity of both Flap Position Sensors as per the following table. Replace as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
Channel A (connector P1) Channel B (connector P2) Between pin 1 and pin 2 110Ω Between pin 1 and pin 2 110Ω Between pin 3 and pin 4 75Ω Between pin 3 and pin 4 75Ω Between pin 5 and pin 6 75Ω Between pin 5 and pin 6 75Ω NOTE: A swap of both Flap Position Sensors can also be done to confirm a defective Flap Position Sensor.
- Do wiring check between FCU connectors A124AP1/ A124BP1 and SPC connectors A178AP1 /A178BP1. Repair/replace as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace SPC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace FCU.
- Do close out.