03/18/24
Message Overview
Message Description:
IASC 1 or IASC 2 has detected a loss of power or a low speed condition for the Avionics Cooling Fan.
Possible Causes:
- Avionics Cooling Fan (B3)
- Right DC Power-Center Avionics Cooling Fan Power Relay (K154)
- Left DC Power-Center Avionics Cooling Fan Power Relay (K153)
- Right DC Power-Center Avionics Cooling Fan Control Relay (K154)
- Junction Box 3 (JB3)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
NOTE:
- If no rotation from the avionics cooling fan (B3) is sensed within 10 seconds,the avionics cooling valve (MPE14) in the belly goes to open and all power is lost at the avionics cooling fan motor.. Therefore, no voltage at stud T14 and T15 after 10 seconds. So, the avionics cooling fan (B3) is faulty.
Quick Links:
| Removal of the Avionics Cooling Fan | AMM 21-23-05-000-801 |
| Installation of the Avionics Cooling Fan | AMM 21-23-05-400-801 |
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Removal of the Junction Box JB3 | AMM 24-63-09-000-802 |
| Installation of the Junction Box JB3 | AMM 24-63-09-400-802 |
| Removal of the DC Power Center (DCPC) | AMM 24-61-01-000-801 |
| Installation of the DC Power Center (DCPC) | AMM 24-61-01-400-801 |
| Removal of the DC Power-Center Relays | AMM 24-61-81-000-801 |
| Installation of the DC Power-Center Relays | AMM 24-61-81-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Make sure the EMER DEPRESS PBA is not pushed. (Confirm by PBA light test).
- Check that the fan is running.
- If fan is running, go to step 7.
- If fan is not running, continue with next step.
- Do wiring checks between Avionics Fan, LDCPC T15 and RDCPC T14.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Remove LDCPC and RDCPC one at a time to isolate short circuit. (Replace DCPC or relays K153/K9 inside DCPC as required)
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring checks between avionics fan B3P1 pin C and GS2173 (aircraft ground).
- If system checks are good, do close out.
- If fault remains, go to step 8.
- Do wiring checks between avionics fan, JB3, IASC1 and IASC2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap IASCs. (IASC1 is the primary controller for the operation of the Fan).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace avionics fan.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace DB2/JB3.
- Do close out.