Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/02/21

Message Overview:

Message Name:

NO SIGNAL / OUT OF RANGE

Message Code:

B3-006661

Associated CAS:

R BLEED FAIL
(Caution)

Reporting LRU: DIFF PRESS SNSR 2
System Description: 21-51-00
Schematic Diagram: 21-61-00
Wiring Diagram: 21-61-25

Message Description:

The DIFFERENTIAL PRESSURE SENSOR 2 is detected failed. No signal is received or the signal is out of range. Check the sensor or the wiring to the sensor and the IASC # 2.

Possible Causes:

  • Differential Pressure Sensor 2 (MT24)
  • Integrated Air System Controller (IASC #2) (A56)
  • Junction Box 2 (JB2)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Integrated Air System (IASC) Controller AMM 21-31-01-000-801
Installation of the Integrated Air System (IASC) Controller AMM 21-31-01-400-801
Removal of the Differential Pressure Sensor AMM 21-51-03-000-801
Installation of the Differential Pressure Sensor AMM 21-51-03-400-801
Removal of the Junction Boxes AMM 24-63-01-000-802
Installation of the Junction Boxes AMM 24-63-01-400-802
Operational Test of the Bleed Air System AMM 36-11-00-710-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02
Electrical Connectors - Maintenance Practice - ALL SPM 20-20-00-02

Troubleshooting Recommendations:

  1. Reset the R WING / BLD LK circuit breakers CB2-E10.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  2. Swap the Differential Pressure Sensor 2 with the Differential Pressure Sensor 1.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  3. Do wiring check between the Differential Pressure Sensor 1 (MT24) and the IASC 2. Repair as required.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  4. Swap the IASC 2 with the IASC 1.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  5. Do wiring check between the Differential Pressure Sensor 2 (MT24) and the JB 2. Repair as required.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  6. Do wiring check of JB2. Replace Junction Box #2 as required.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  7. Do wiring check of JB2 and the Circuit Breaker CB2-E10. Repair as required.
  8. Do close out.