Message Overview:
Message Description:
Both channels of the PACK INLET TEMPERATURE SENSOR are detected failed. Check for sensor failure.
Possible Causes:
- Pack Inlet Temperature Sensor (PITS) (MT25)
- Integrated Air System Controller 1 (IASC1) (A55)
- Integrated Air System Controller 2 (IASC2) (A56)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Pack Inlet Temperature-Sensor | AMM 21-61-33-000-801 |
| Installation of the Pack Inlet Temperature-Sensor | AMM 21-61-33-400-801 |
| Operational Test of the Bleed Air System | AMM 36-11-00-710-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset PRESS 1 / PACK circuit breaker CB1-D14, L WING / BLD LK circuit breaker CB1-E10 and PRESS 2 / TRIM circuit breaker CB2-D14.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap IASCs.
- Do wiring checks between IASC1 A55P1 (pins 48 & 65) and PIT MT25 (pins 1 & 3). Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring checks between IASC2 A56P3 (pins 17 & 18) and PIT MT25 (pins 4 & 6). Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap PITS (MT25) with HATS (MT27).
- Do close out.
Pack Inlet Temperature Sensor Resistance
|
|
|