08/10/21
Message Overview:
Message Description:
The avionics relay K97 has been detected failed, by IASC1A and/or IASC2A.
Possible Causes:
- Relay (K97) (JB3/DB2)
- Integrated Air System Controller (IASC1) (A55)
- Integrated Air System Controller (IASC2) (A56)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Relay K97 (and Relay K150) live inside JB3, on Card DB2. Power to K97 comes through K150 from two sources. IASC1A and IASC2A monitor the same "D" leg of relay K97. If the MDC fault is being reported by one IASC only, then suspect the IASC that is reporting the fault as they share the same bus.
Quick Links:
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Removal of the Junction Box Circuit Cards | AMM 24-63-05-000-802 |
| Installation of the Junction Box Circuit Cards | AMM 24-63-05-400-802 |
| Removal of the Junction Box JB3 | AMM 24-63-09-000-802 |
| Installation of the Junction Box JB3 | AMM 24-63-09-400-802 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Ensure the EMER DEPRESS PBA is not pushed in.
- Pull the circuit breakers CB5-B2 and CB6-B2.
- Disconnect A55P2 of the IASC1 and MPE14P1 of the avionics cooling valve.
- Do a continuity check between A55P1 Pin 19 and MPE14P1 Pin 3.
- If system checks are good, go step.
- If fault remains, continue with next step.
- Interchange IASCs.
- Replace the electronic card DB/JB3.
- Do close out.