02/12/21
Message Overview:
Message Description:
L-ADC-1 data absent at L-IOC.
Possible Causes:
- Left Air Data Computer (ADC) 1 (A1)
- Left Input/Output Concentrator Unit (IOC) 1 (A4)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Removal of the Air Data Computer | AMM 34-13-01-000-801 |
| Installation of the Air Data Computer | AMM 34-13-01-400-801 |
| Standard Practices - Wire Replace | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset L IAPS (CB1-B6) and AIR DATA 1 (CB1-C1) circuit breakers
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do a wiring check of the ARINC 429 data bus L-ADC-1 from IAPS connector A4P1 to ADC 1 connector A1P1. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap IOCs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap ADCs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace ICC.
- Do close out.