Message Overview:
Message Description:
No R-IRS-1 data received at R-IOC but data received at SPC.
Possible Causes:
- Right Input/ Output Concentrator Unit 2 (IOC 2) (A4-IOC2)
- Junction Box 4 (JB4)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Removal of the Inertial Reference Unit (IRU) | AMM 34-45-01-000-801 |
| Installation of the Inertial Reference Unit (IRU) | AMM 34-45-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices -& ;Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset R IAPS (CB2-B6) circuit breaker.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap IOCs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do a wiring check of the ARINC 429 data bus R-IRS-1 from IAPS connector A4P101, through Junction Box 4, to IRU 2 connector A232P1. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace ICC.
- Do close out.