Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

02/23/21

Message Overview:

Message Name:

NO SATCOM MAINT OUTPUT

Message Code:

B3-007977

Associated CAS:

None

Reporting LRU: SAT 2X00
System Description: 23-15-00
Schematic Diagram: 23-15-00
Wiring Diagram: 23-15-01

Message Description:

SATCOM MAINTENANCE data bus is absent at R IOC.

Possible Causes:

  • SATCOM Satellite Data Unit (SDU)
  • Right Input/Output Concentrator Unit (IOC) 2 (A4-IOC2)
  • Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the SATCOM Satellite Data Unit (SDU) AMM 23-15-01-000-801
Installation of the SATCOM Satellite Data Unit (SDU) AMM 23-15-01-400-801
Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) AMM 31-45-01-000-801
Installation of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) AMM 31-45-01-400-801
Removal of the Input/Output Concentrator Unit (IOC) AMM 31-45-05-000-801
Installation of the Input/Output Concentrator Unit (IOC) AMM 31-45-05-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02
Electrical Connectors - Maintenance Practice - ALL SPM 20-20-00-02

Troubleshooting Recommendations:

  1. Reset SATCOM (CB4-D2) circuit breaker.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  2. Swap IOCs.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  3. Do wiring check of ARINC 429 data bus SDU-4 from SDU connector A82BP1 to IAPS connector A4P103. Repair/replace as required.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  4. Replace SDU.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  5. Replace Integrated-Avionics Processor System (IAPS) Card Cage (ICC).
  6. Do close out.