Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/13/22

Message Overview:

Message Name:

R LOGIC/RBTC/LBTC FAULT

Message Code:

B3-007828

Associated CAS:

ELECTRICAL FAULT
(Caution)

ELECTRICAL FAULT
(Advisory)

Reporting LRU: R LOGIC PCB
System Description: 24-61-00
Schematic Diagram: 24-61-00
Wiring Diagram: 24-61-03

Message Description:

The Right DC Power-Center Primary-Logic has failed.

Possible Causes:

  • Left Bus Tie Contactor (LBTC) (K79)
  • Right DC Power-Center Primary-Logic (RLOG) (PCB4)
  • Right DC Power-Center Protection (RPROT) (PCB2)
  • Right Auxiliary Bus Contactor (RAUXC) (K76)
  • Right Battery Contactor (RBATC) (K74)
  • Right Bus Tie Contactor (RBTC) (K80)
  • Right Essential Bus Contactor (RESSC) (K78)
  • Right DC Power Center (RDCPC) (A36)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW300-24-0013 - Loss of Normal Electrical Power
  • AW300-24-0038 - Nuisance "ELECTRICAL FAULT" CAS Message Upon Engine or APU Shut Down
  • AW300-24-0115 - Introduction of Improved Generator P/N A3579-102
  • AW300-24-0132 - Power Module (PMOD) P/N R3608-011 - Generator Failures at High Engine Speed
  • AW300-24-0137 - Y06 Electrical System Upgrade
  • AW300-24-0162 - Service Bulletin 100-24-20 - DC Power Center (DCPC) System - Inspection and Replacement of Internal Fuses in the L/H and R/H DC Power Center (DCPC)

Forum Articles/Infoservice/Newsletter: None

NOTE: If the Aircraft is energized by the External power while both batteries are disconnected, this MDC Fault message will appear. Return the Aircraft to the normal configuration prior to continuing with this procedure.

Quick Links:

Removal of DC Power Center (DCPC) AMM 24-61-01-000-801
Installation of DC Power Center (DCPC) AMM 24-61-01-400-801
Removal of the DC Power-Center Primary-Logic AMM 24-61-73-000-801
Installation of the DC Power-Center Primary-Logic AMM 24-61-73-400-801
Removal of the DC Power-Center Protection AMM 24-61-77-000-801
Installation of the DC Power-Center Protection AMM 24-61-77-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02
Electrical Connectors - Maintenance Practice - ALL SPM 20-20-00-02

Troubleshooting Recommendations:

  1. Check on the EICAS if one of the following messages is posted.

    1. If one or many CAS messages are present, continue with the associated troubleshooting procedures.
    2. If none are present, continue with next step.

  2. Check in the MDC if one of the following faults is logged in the current faults page or in the fault history page.

    1. If one or many faults are present, continue with the associated troubleshooting procedures.
    2. If none are present, continue with next step.

  3. Interchange the Right DC Power-Center Primary-Logic (PCB4) with the Left DC Power-Center Primary-Logic (PCB3). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective DC Power-Center Primary-Logic.

  4. Swap the Right DC Power-Center Protection (PCB2) with the Left DC Power-Center Protection (PCB1). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective DC Power-Center Primary-Logic.

  5. Replace Right DC Power Center (A36).
  6. Do close out.