Message Overview:
Message Description:
The HYD GEN Isolation Valve is failed partially or fully open.
Possible Causes:
- Hydraulic-Motor Driven Generator (HMDG) (G4)
- Hydraulic-Motor Driven Generator Control Unit (HMDG GCU) (A206)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- SB100-24-04 - MODIFICATION - EMERGENCY DC-POWER SYSTEM - Installation of the Hydraulic Motor Driven Generator (HMDG) Option (C24-300)
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Operational Test of the HMDG System | AMM 24-33-00-710-801 |
| Removal of the Hydraulic-Motor Driven Generator (HMDG) | AMM 24-33-01-000-801 |
| Installation of the Hydraulic-Motor Driven Generator (HMDG) | AMM 24-33-01-400-801 |
| Removal of the Generator Control Unit (GCU)-Emergency | AMM 24-33-09-000-801 |
| Installation of the Generator Control Unit (GCU)-Emergency | AMM 24-33-09-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Do wiring check as per the following table:
From To Results HMDG GCU conn A206P2 - pin A HMDG conn G4P4 - pin 1 HMDG GCU conn A206P2 - pin B HMDG conn G4P4 - pin 2 HMDG GCU conn A206P2 - pin M HMDG conn G4P3 - pin C HMDG GCU conn A206P2 - pin P Aircraft Ground - If the check is not satisfactory, repair/replace defective wiring.
- If the check is satisfactory, continue with next step.
- Replace HMDG (G4). Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace HMDG GCU (A206).
- Do close out.