Message Overview:
Message Description:
The Horizontal Stabilizer Electronic Control Unit (HST ECU) has detected a Primary Engage Relay fault.
NOTE: Consequently the failures described above will trigger in the MDC the corresponding Label 352 bit 21.
Possible Causes:
- DC Power Center (DCPC) Relay (LH) (K44)
- Horizontal-Stabilizer-Trim Electronic-Control Unit (HST ECU) (A130)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| Standard Aircraft Configuration for Maintenance | AMM 12-00-00-867-803 |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 |
| Electrostatic-Discharge Safety Precautions | AMM 24-00-00-910-802 |
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 |
| Removal of the DC Power-Center Relays | AMM 24-61-81-000-801 |
| Installation of the DC Power-Center Relays | AMM 24-61-81-400-801 |
| Removal of the Horizontal-Stabilizer-Trim Electronic-Control Unit (HST ECU) | AMM 27-41-21-000-801 |
| Installation of the Horizontal-Stabilizer-Trim Electronic-Control Unit (HST ECU) | AMM 27-41-21-400-801 |
| Operational Test of the Horizontal-Stabilizer-Trim Electronic-Control Unit (HST ECU) | AMM 27-41-21-710-801 |
Troubleshooting Recommendations:
- Pull the circuit breakers that follow and reset after a few seconds:
- If system checks are good, do close out.
- If fault remains, continue with next step.
PRI STAB TRIM/RUD LIM CB1 - B15 SEC STAB TRIM/RUD LIM CB2 - B13 PRI STAB MOTOR LCDPC - A4 SEC STAB MOTOR RDCPC - A5 - Interchange Engage Relays K44 with K45.
- If fault transfer to SEC replace defective relay, do close out.
- If fault remains, continue with next step.
- Do wiring checks between relays and HST ECU. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace HST ECU.
- Do close out.