Message Overview:
Message Description:
Loss of redundant resolver outputs from L AOA reported by SPC A.
Possible Causes:
- Angle-Of-Attack Sensor (LH) (A141)
- Stall Protection Computer (SPC) (A178)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Functional Test of the Stall Protection System | AMM 27-32-00-720-801 |
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 |
| Removal of the Angle-of-Attack Sensor | AMM 27-32-09-000-801 |
| Installation of the Angle-of-Attack Sensor | AMM 27-32-09-400-801 |
| Functional Test of the Angle-of-Attack Sensor | AMM 27-32-09-720-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset the following circuit breakers and perform the Pilot Activated Test (PAT) of the Stall Protection System on the Systems Test control-panel located on the center pedestal.
STALL L PWR CB1-B10 STALL R PWR CB2-B10 - If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between SPC connector A178AP1 and Left AOA sensor connector A141P1. Replace/repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap AOA sensors.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace SPC.
- Do close out.