Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

03/01/21

Message Overview:

Message Name:

R AOA SENSOR FAIL

Message Code:

B3-007673

Associated CAS:

STALL PROTECT FAIL
(Caution)

R STALL SHAKER FAIL
(Advisory)

Reporting LRU: R AOA SENSOR
System Description: 27-32-00
Schematic Diagram: 27-32-00
Wiring Diagram: 27-32-09

Message Description:

Right Angle-of-Attack Sensor is reported failed by the Stall Protection Computer.

Possible Causes:

  • Right Angle-of-Attack Sensor (A142)
  • Stall Protection Computer (SPC) (A178)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW300-27-0105 - "STALL PROTECT FAIL" Nuisance CAS Message (20501 - 20999).
  • SB100-27-14 - Modification - Stall Protection System - Introduction of the Stall Protection Computer (SPC) Part No. 822-1792-003 to Correct Loopback ARINC 429 Failure Messages

Forum Articles/Infoservice/Newsletter: None

If the 'STALL PROTECT FAIL' message appears after SPC power up, reset the SPC circuit breakers 'SPC CH A' (CBP1-B10) and 'SPC CH B' (CBP2-B10).

If the message appears following a PAT, then reset the SPC circuit breakers 'SPC CH A' (CBP1-B10) and 'SPC CH B' (CBP2-B10). Perform another PAT and make sure the message does not come back.

Enter the MAINTENANCE MAIN MENU. With the CCP 2, make the selection of the SYSTEM PARAMETERS page 2/2. You will be able to monitor the integrity of the R AOA vane position.

  • Move the right AOA vane to the up stop: The compensated body AOA is between 58.66 degrees to 65.50 degrees on the MFD 2.
  • Move the right AOA vane to the down stop: The compensated body AOA is between -53.50 degrees to -60.34 degrees on the MFD 2.

Quick Links:

Functional Test of the Stall Protection System AMM 27-32-00-720-801
Removal of the Stall Protection Computer AMM 27-32-01-000-801
Installation of the Stall Protection Computer AMM 27-32-01-400-801
Removal of the Angle-of-Attack Sensor AMM 27-32-09-000-801
Installation of the Angle-of-Attack Sensor AMM 27-32-09-400-801
Functional Test of the Angle-of-Attack Sensor AMM 27-32-09-720-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02
Electrical Connectors - Maintenance Practice - ALL SPM 20-20-00-02

Troubleshooting Recommendations:

  1. Reset the following circuit breakers and perform the Pilot Activated Test (PAT) of the Stall Protection System on the Systems Test control-panel located on the center pedestal.

    STALL L PWR CB1-B10
    STALL R PWR CB2-B10

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  2. Do wiring check between SPC connector A178BP1 and Right AOA sensor connector A142P1. Replace/repair as required.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  3. Swap AOA sensors.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  4. Replace SPC.
  5. Do close out.