03/01/21
Message Overview:
Message Description:
The Flap Control Unit (Right Flap Position Indication Unit - R FPIU) is reporting a failure with the Right Flap Position Sensor.
Possible Causes:
- Right Flap Position Sensor (MPE78)
- Flap Control Unit (FCU) (A124)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-27-0058 - Flap Control Unit - CAS Messages Reset procedure
Forum Articles/Infoservice/Newsletter: None
If Flap Control Unit (FCU) PN: 2257A0000-02 is installed, reset procedure included in AW300-27-0058 may clear the fault.
Quick Links:
| Removal of the Flap Control Unit (FCU) | AMM 27-51-05-000-801 |
| Installation of the Flap Control Unit (FCU) | AMM 27-51-05-400-801 |
| Operational Test of the Flap Control Unit (FCU) | AMM 27-51-05-710-801 |
| Electrical Rigging of the Flap System | AMM 27-52-00-820-801 |
| Removal of the Flap Position Sensor | AMM 27-52-17-000-802 |
| Installation of the Flap Position Sensor | AMM 27-52-17-400-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset the following circuit breakers.
FLAP R IND CB2-B12 FLAP L IND CB1-B13 FLAP CTRL CB1-B14 - Reset the FCU by pressing the FCU reset button on the MAINTENANCE TEST control-panel.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do the Electrical Rigging of the Flap system.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between FCU connectors A124AP1/ A124BP1 and Right Flap Position Sensor connectors A78AP1/A78BP1. Repair/replace as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Check internal wiring integrity of Right Flap Position Sensor as per the following table.
- If wiring is confirmed good, go to step 7.
- If wiring is found defective, continue with next step.
Channel A Channel B MPE78P1 Value MPE78P2 Value Between pin 1 and pin 2 104Ω to 124Ω Between pin 1 and pin 2 104Ω to 124Ω Between pin 3 and pin 4 73.8Ω to 90.2Ω Between pin 3 and pin 4 73.8Ω to 90.2Ω Between pin 5 and pin 6 73.8Ω to 90.2Ω Between pin 5 and pin 6 73.8Ω to 90.2Ω NOTE: A swap of both Flap Position Sensors can also be performed to confirm a defective Flap Position Sensor.
- Replace Right Flap Position Sensor.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace FCU.
- Do close out.