Message Overview:
Message Description:
No C-FCU-1 bus data through RDC to SECU 2.
Possible Causes:
- LH Flap Position Sensor (MPE77)
- Spoiler Electronic-Control Unit 1 (SECU 1) (A118)
- Flap Control Unit (FCU) (A124)
- Remote Data Concentrator (RDC) (A13)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Equation: No M-FCU-1 data thru A-SPC and L-IOC to R-SECU. Verify R-SECU input, wiring, failed
M-FCU-1 output, failed A-SPC or L-IOC input.
Quick Links:
| Removal of the Flap Control Unit (FCU) | AMM 27-51-05-000-801 |
| Installation of the Flap Control Unit (FCU) | AMM 27-51-05-400-801 |
| Operational Test of the Flap Control Unit (FCU) | AMM 27-51-05-710-801 |
| Removal of the Flap Position Sensor | AMM 27-52-17-000-802 |
| Installation of the Flap Position Sensor | AMM 27-52-17-400-802 |
| Removal of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-000-801 |
| Installation of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-400-801 |
| Electronic Rigging of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-820-801 |
| Electronic Rigging of the Spoiler Electronic-Control Unit (SECU) | AMM 27-61-05-820-802 |
| Removal of the Remote Data Concentrator (RDC) | AMM 31-41-05-000-802 |
| Installation of the Remote Data Concentrator (RDC) | AMM 31-41-05-400-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Swap Flap Position Sensors.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform wiring checks between LH Flap Position Sensor MPE77 and FCU A124. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap SECUs.
NOTE: Perform electronic rigging of both SECUs when either SECU is swapped or replaced. The intent is if a SECU that is being installed was previously rigged in a different location in the same aircraft or it is being installed in a different aircraft or the SECU is a spare part it requires electronic rigging (AMM 27-61-05-820-802) per the instructions in AMM TASK 27-61-05-400-801 Installation of the Spoiler Electronic-Control Unit (SECU).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace FCU.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace RDC.
- Do close out.