Message Overview:
Message Description:
Left Input/Output Concentrator is not receiving data from Stall Protection Computer (SPC) channel A.
Possible Causes:
- Left Input/Output Concentrator (IOC) (A4-IOC1)
- Stall Protection Computer (SPC) (A178)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| General Setup for Maintenance | |
|---|---|
| Standard Aircraft Configuration for Maintenance | AMM 12-00-00-867-803 |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 |
| Electrostatic Discharge Safety Precautions | AMM 24-00-00-910-802 |
| Maintenance Tasks | |
| Removal of the Junction Box JB3 | AMM 24-63-09-000-802 |
| Installation of the Junction Box JB3 | AMM 24-63-09-400-802 |
| Functional Test of Junction Box JB3 | AMM 24-63-09-720-801 |
| Replacement of DC Circuit Breakers | AMM 24-65-00-960-801 |
| Operational Test of the Stall Protection System (SPS) | AMM 27-32-00-710-801 |
| Functional Test of the Stall Protection System | AMM 27-32-00-720-801 |
| Removal of the Stall Protection Computer | AMM 27-32-01-000-801 |
| Installation of the Stall Protection Computer | AMM 27-32-01-400-801 |
| Operational Test of the Integrated-Avionics Processor System (IAPS) | AMM 31-45-00-710-801 |
| Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Operational Test of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-710-801 |
Troubleshooting Recommendations:
- Reset the following circuit breakers and perform the Pilot Activated Test (PAT) of the Stall Protection System on the Systems Test control-panel located on the center pedestal.
STALL L PWR CB1-B10 STALL R PWR CB2-B10 - If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check of ARINC 429 A-SPC-1 data bus between SPC connector A178AP1, Junction Box #3 and IAPS connector A4P1.
- If system checks are good, do close out.
- If fault remains, continue with next step.
NOTE: An internal short of any LRU connected to this ARINC bus may cause the fault.
- Interchange IOCs.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace SPC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace Integrated-Avionics Processor System (IAPS) Card Cage (ICC).
- Do close out.