Message Overview:
Message Description:
Left Flap Transmission Brake fault. Replace L FTB. After FTB is replaced, perform FTB test.
Possible Causes:
- Left Flap Transmission Brake (FTB) (A203)
- Flap Control Unit (FCU) (A124)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
NOTES:
- In the MDC system parameters, an FPU PRESS XDCR SIGNAL showing 3740 PSI indicates the FCU has detected a malfunction in the system and does not send the excitation signal to the FPU pressure transducer.
Quick Links:
| Removal of the Flap Transmission Brake | AMM 27-52-19-000-801 |
| Installation of the Flap Transmission Brake | AMM 27-52-19-400-801 |
| Operational Test of the Flap Transmission Brake | AMM 27-52-19-710-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset the following circuit breakers:
FLAP R IND CB2-B12 FLAP L IND CB1-B13 FLAP CTRL CB1-B14 - If system checks are good, do close out.
- If fault remains, continue with next step.
- Reset the FCU by pressing the FCU reset button (ref. AMM ATA 27-52-00).
- If reset is successful, perform an MDC Download (ref. AMM ATA 45-45-00).
- If system checks are good, do operational test of Flap Transmission Brake per AMM and do close out.
- If problem remain continue to next step.
- Do a Flap Transmission Break Resistance Check as follows:
- Remove connectors from Left Flap Transmission Brake and Record Resistance of Solenoid Coils.
NOTE: All are the same P/N and LRU replaceable.FTB Left Side FCU 124AP1 Or FTB A203: Typical Reading A203P1 Solenoid # 1 6J to 5J Pins 1-2 = (Normal ≈ 58Ω) A203P2 Solenoid # 2 6G to 5G Pins 1-2 = (Normal ≈ 58Ω) - If reading is not as specified, replace L FTB per AMM. Do close out.
- If problem remains, continue to next step.
- Remove connectors from Left Flap Transmission Brake and Record Resistance of Solenoid Coils.
- Do Flap Transmission Break Voltage Check as follows:
Release the Flap Transmission Brake with the MDC as follows:
FTB release procedure through MDC:PROCEDURE APPLICABLE RESULT Push the A/ICE, ECS, and FUEL buttons at the same time to access the maintenance diagnostic computer (MDC). MAINTENANCE MAIN MENU shows on the MDC. Use the joystick and ENTER button to select LRU RIGGING. LRU INDEX ALL ATA CHAPTERS page shows on the MDC. Use the joystick and ENTER button to select FLAP CTRL UNIT. The LRU OPERATIONS ATA 27-52 FLAP CTRL UNIT PAGE shows on the MDC. Use the joystick and ENTER button to select RIGGING. The FLAPS RIGGING 1/2 page shows on the MDC. Use the joystick and ENTER button to select START MECHANICAL RIGGING. The FLAP MECHANICAL RIGGING 2/2 page shows on the MDC. Use the joystick and ENTER button to select LH & RH FTB OPEN. The FTB STATUS shows OPEN on the MDC. Record voltages at each connector. Check each with Normal and Alternate flaps. Should be approx 28 VDC.
FTB A203 Left Side Normal Flaps: Alternate Flaps: A203P1 Solenoid # 1 Pin 1 to ground 0 VDC 28 VDC A203P2 Solenoid # 2 Pin 1 to ground 28 VDC 0 VDC - If reading is not as specified, do wiring check from FCU to FTB. Repair as required.
- If problem remains, continue with next step.
- Replace L FTB per AMM.
- Do close out.