03/02/21
Message Overview:
Message Description:
No lateral acceleration data from L IRS. L IOC is not reporting L-IRS-1 data bus missing.
Possible Causes:
- Stall Protection Computer (SPC) (A178)
- Junction Box 1 (JB1)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-45-0016 - MDC Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB1 | AMM 24-63-01-000-802 |
| Installation of the Junction Box JB1 | AMM 24-63-01-400-802 |
| Functional Test of Junction Box JB1 | AMM 24-63-01-720-801 |
Troubleshooting Recommendations:
- Reset STALL L PWR (CB1-B10) circuit breaker.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do the wiring check of the ARINC 429 data bus L-IRS-1 between SPC connector A178AP1 pins 33 & 45, through Junction Box 1, and IRU 1 connector A233P1 pins 43 & 44. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace SPC.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do close out.