Message Overview:
Message Description:
Fuel Quantity Gauging Computer has no ARINC input from L GP-5 bus.
Possible Causes:
- Junction Box 1 (JB1)
- Junction Box 2 (JB2)
- Left Input/Output Concentrator (IOC) (A4-IOC1)
- Fuel Quantity Gauging Computer (FQGC) (A57)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
If the MDC message 'No L-GP-5 Input' is in the Fault Message History (FMH) and FQGC BIT passes, this should be considered a transitory condition.
Quick Links:
| Pressure Refueling | AMM 12-11-01-650-801 |
| Suction Defueling | AMM 12-11-09-650-801 |
| Removal of the Junction Box JB2 | AMM 24-63-05-000-803 |
| Installation of the Junction Box JB2 | AMM 24-63-05-400-803 |
| Functional Test of the Junction Box JB2 | AMM 24-63-05-720-801 |
| Drain Water from the Fuel Tank | AMM 28-10-00-680-801 |
| Built-In Test of the Fuel-Quantity Gauging System | AMM 28-41-00-740-801 |
| Removal of the Fuel Quantity Computer | AMM 28-41-01-000-801 |
| Installation of the Fuel Quantity Computer | AMM 28-41-01-400-801 |
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Operational Test of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-710-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Make sure the Refuel/Defuel panel is set to OFF and reset CB3-C3 (FUEL QTY 1), CB4-C3 (FUEL QTY 2), CB1-B6 (L IAPS), waiting 10 seconds before pushing the breakers back.
- If fault is no longer in the Current Fault report, no other action is necessary.
- If fault is still present, go to next step.
- Verify if other LRUs have reported a missing ARINC input from L GP-5 bus.
- If YES, troubleshoot L IOC card.
- If NO, go to next step.
- Interchange IOC cards.
- If fault follows, replace faulty IOC card.
- If fault remains, re-install IOC cards to their original position and go to next step.
- Carry out wiring checks.
FROM TO EXPECTED RESULTS: FQGC A57BP1 pin 77 JB1 JB1AP1 pin F7 Continuity FQGC A57BP1 pin 91 JB1 JB1AP1 pin G7 Continuity - If wiring defects are found, repair/replace as required.
- If wiring is found serviceable, go to next step.
- Re-rack the Fuel Quantity Gauging Computer (FQGC). Is the fault message still present?
- If YES, go to next step.
- If NO, do close out.
- Replace FQGC.
- Do close out