Message Overview:
Message Description:
FQGC-A bus data invalid or missing to RDC.
Possible Causes:
- Fuel Quantity Gauging Computer (FQGC) (A57)
- Remote Data Concentrator (RDC) (A13)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/ Service Bulletin:
- AW300-28-0398 - SmartFix Plus Fuel System Troubleshooting Updates
Forum Articles/Infoservice/Newsletter: None
NOTE: Flight crew should be aware that if 'FUEL QTY FAULT' or 'FUEL QTY FAIL' CAS is posted, they should verify fuel synoptic page and report any abnormal conditions or parameters.
Quick Links:
| Standard Aircraft Configuration for Maintenance | AMM 12-00-00-867-803 |
| Use of Fuel Biocide Additive When Pressure Refueling | AMM 12-11-01-620-801 |
| Pressure Refueling | AMM 12-11-01-650-801 |
| Use of Fuel Anti-Icing Additive When Pressure Refueling | AMM 12-11-01-660-801 |
| Suction Defueling | AMM 12-11-09-650-801 |
| Use of Fuel Biocide Additive When Gravity Refueling | AMM 12-11-13-620-801 |
| Gravity Refueling | AMM 12-11-13-650-801 |
| Use of Fuel Anti-Icing Additive When Gravity Refueling | AMM 12-11-13-660-801 |
| Microbial Growth Test | AMM 12-11-28-280-801 |
| Fuel-System Safety Precautions | AMM 28-00-00-910-801 |
| Cleaning of the Fuel Tank | AMM 28-10-00-160-801 |
| Biocide Treatment of the Fuel Tank | AMM 28-10-00-620-801 |
| Drain Water from the Fuel Tank | AMM 28-10-00-680-801 |
| Prepare Fuel Tank for Access | AMM 28-10-00-840-801 |
| Removal of Fuel Fumes | AMM 28-10-00-840-802 |
| Close the Fuel Tank after Maintenance | AMM 28-10-00-840-803 |
| General Visual Inspection of the Fuel Storage System | AMM 28-10-00-210-801 |
| Operational Check for Water in the Fuel | AMM 28-10-00-750-801 |
| Component Location | AMM 28-11-00-992-801 |
| Component Location | AMM 28-41-00-992-801 |
| Built-In Test of the Fuel-Quantity Gauging System | AMM 28-41-00-740-801 |
| Removal of the Fuel Quantity Computer | AMM 28-41-01-000-801 |
| Removal of the Fuel Quantity Probe | AMM 28-41-13-000-801 |
| Installation of the Fuel Quantity Probe | AMM 28-41-13-400-801 |
| Removal of the Fuel Quantity Probe with Compensator | AMM 28-41-13-000-802 |
| Installation of the Fuel Quantity Probe with Compensator | AMM 28-41-13-400-802 |
| Capacitance Check of the Fuel Quantity Probes | AMM 28-41-13-760-801 |
| Cleaning of the Fuel Quantity Probes | AMM 28-41-13-160-801 |
| Removal of the Remote Data Concentrator (RDC) | AMM 31-41-05-000-802 |
| Installation of the Remote Data Concentrator (RDC) | AMM 31-41-05-400-802 |
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Operational Test of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-710-801 |
| Data Download from the Maintenance Diagnostic Computer (MDC) | AMM 45-45-01-970-802 |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02-01 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02-01 |
Troubleshooting Recommendations:
- Make sure Refuel/Defuel panel is set to OFF and reset the following circuit breakers, waiting 10 seconds before pushing the breakers back.:
Circuit Breaker Name CB3-C3 FUEL QTY 1 CB4-C3 FUEL QTY 2 CB1-D2 EICAS RDC A CB2-D2 EICAS RDC B - If the cyan 'FUEL QTY FAULT' EICAS message is still displayed, go to next step.
- If the cyan 'FUEL QTY FAULT' EICAS message is no longer displayed, do close out.
- Verify fuel synoptic page for any MAGENTA parameters other than fuel quantities.
- If any abnormal MAGENTA indications other than fuel quantities are displayed on the Fuel Synoptic page, or were reported displayed by pilots at a time that can be correlated to B3-006793, replace RDC.
- If there are no abnormal MAGENTA parameters, go to next step.
- Re-rack the Fuel Quantity Gauging Computer (FQGC). Is the fault message still present?
- If YES, go to next step.
- If NO, do close out.
- Carry out wiring checks per Table 1. Repair or replace any defective wiring as required.
Table 1 RDC (A13) FQGC (A57) Connector Pin + Connector Pin - Expected Result A13DP1 A1 A57BP1 67 Continuity A13DP1 B1 A57BP1 68 Continuity - Do power checks per Table 2. Repair or replace any defective wiring as required.
Table 2 CONNECTOR PINS (28 VDC) PIN (ground) Expected Results A57BP1 95 97 ≈28 VDC - If wiring is found serviceable, replace FQGC.
- If fault continues, replace RDC.
- Do close out.