Message Overview:
Message Description:
FQGC-B bus data invalid or missing to RDC.
Possible Causes:
- Fuel Quantity Gauging Computer (FQGC) (A57)
- Remote Data Concentrator (RDC) (A13)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/ Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
- Flight crew should be aware that if 'FUEL QTY FAULT' or 'FUEL QTY FAIL' CAS is posted, they should verify fuel synoptic page and report any abnormal conditions or parameters.
Quick Links:
| Pressure Refueling | AMM 12-11-01-650-801 |
| Suction Defueling | AMM 12-11-09-650-801 |
| Drain Water from the Fuel Tank | AMM 28-10-00-680-801 |
| Built-In Test of the Fuel-Quantity Gauging System | AMM 28-41-00-740-801 |
| Removal of the Fuel Quantity Computer | AMM 28-41-01-000-801 |
| Installation of the Fuel Quantity Computer | AMM 28-41-01-400-801 |
| Removal of the Remote Data Concentrator (RDC) | AMM 31-41-05-000-802 |
| Installation of the Remote Data Concentrator (RDC) | AMM 31-41-05-400-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Make sure Refuel/Defuel panel is set to OFF and reset the following circuit breakers, waiting 10 seconds before pushing the breakers back:
Circuit Breaker Name CB3-C3 FUEL QTY 1 CB4-C3 FUEL QTY 2 CB1-D2 EICAS RDC A CB2-D2 EICAS RDC B - If the amber 'FUEL QTY FAIL' EICAS message is still displayed, go to next step.
- If the amber 'FUEL QTY FAIL' EICAS message is no longer displayed, do close out.
- Verify fuel synoptic page for any MAGENTA parameters other than fuel quantities.
- If any abnormal MAGENTA indications other than fuel quantities are displayed on the Fuel Synoptic page, or were reported displayed by pilots at a time that can be correlated to B3-006794, replace RDC.
- If there are no abnormal MAGENTA parameters, go to next step.
- Re-rack the Fuel Quantity Gauging Computer (FQGC). Is the fault message still present?
- If YES, go to next step.
- If NO, do close out.
- Carry out wiring checks per Table 1.
Table 1 Connector Pin + Connector Pin - Expected Result A13EP1 A1 A57BP1 79 Continuity A13EP1 B1 A57BP1 78 Continuity - Do power checks per Table 2. Repair or replace any defective wiring as required.
Table 2 CONNECTOR PINS (28 VDC) PIN (ground) Expected Results A57BP1 105 103 ≈28 VDC - If wiring is found serviceable, replace FQGC.
- If fault continues, replace RDC.
- Do close out.