03/10/21
Message Overview:
Message Description:
L-IRS-2 bus data absent at Primary Flight Display (PFD) 1 and NOT absent at Multi-Function Display (MFD) 1.
Possible Causes:
- Junction Box 1 (JB1)
- Primary Flight Display 1 (PFD) (A27)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB1 | AMM 24-63-01-000-802 |
| Installation of the Junction Box JB1 | AMM 24-63-01-400-802 |
| Removal of the Adaptive Flight-Display Unit | AMM 31-61-01-000-801 |
| Installation of the Adaptive Flight-Display Unit | AMM 31-61-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset L PFD (CB1-C3) and L PFD HTR (CB3-F6) circuit breakers.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap AFDs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do wiring check of the ARINC 429 data bus L-IRS-2 from PFD 1 connector A27P1 to Junction Box #1 connector JB1AP1 or respective Test Points. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace Junction Box #1.
- Do close out.