03/10/21
Message Overview:
Message Description:
The Remote Data Concentrator (RDC) is not receiving the outboard BCU ARINC signal.
NOTE: This code will be logged during power interruptions (C/B reset, BCU internal reset).
Possible Causes:
- Brake Control Unit (BCU) (A67)
- Remote Data Concentrator (RDC) (A13)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of Remote Data Concentrator (RDC) | AMM 31-41-05-000-802 |
| Installation of Remote Data Concentrator (RDC) | AMM 31-41-05-400-802 |
| Removal of the Brake Control Unit | AMM 32-43-01-000-801 |
| Installation of the Brake Control Unit | AMM 32-43-01-400-801 |
| Data Download from the Maintenance Diagnostic Computer (MDC) | AMM 45-45-01-970-802 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Electrical Wiring - Continuity Test - Adjustment/Test | SPM 20-12-01-05 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- If other brake system related fault codes are shown in B3-006385 fault code time frame, troubleshoot the other codes first.
NOTE: This code will be logged during power interruptions (C/B reset, BCU internal reset). - Verify that there are no R ESS BUS related CAS messages. Troubleshoot as required.
- Reset the following circuit breakers.
Location CB Number CB Names Zone RCBP C15 OUTBD BRAKES 212 RCBP D2 RDC B 212 - If fault disappears, no other action is required.
- If fault is still shown, go to next step.
- Carry out a wiring check per the following table:
From Connector Pin To Connector Pin A67P1 (BCU) 54 A13EP1 (RDC) 3A A67P1 (BCU) 55 A13EP1 (RDC) 3B - Repair as required.
- If wiring is found serviceable, go to next step.
- Carry out a power check per the following table:
From Connector Pin To Connector Pin Expected Results A67P1 (BCU) 4 A67P1 (BCU) 5 ≈ 28 VDC - Repair as required.
- If no fault found, replace BCU.