Message Overview:
Message Description:
The temp probe I/O for the left ADC is failed.
Possible Causes:
- Left Air Data Computer (ADC 1) (A1)
- Total Air Temperature (TAT) Probe (A16)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Total Air Temperature (TAT) Probe | AMM 34-11-13-000-801 |
| Installation of the Total Air Temperature (TAT) Probe | AMM 34-11-13-400-801 |
| Removal of the Air Data Computer | AMM 34-13-01-000-801 |
| Installation of the Air Data Computer | AMM 34-13-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset AIR DATA 1 (CB1-C1) circuit breaker.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do the wiring check between ADC 1 connector A1P1 and TAT Probe connector A16P1. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Measure the resistance of the TAT Probe Sensing Element 1 between pin 3 and pin 4.
- If the resistance is approx. 500 Ω, go to step 5.
- If the resistance is not approx. 500 Ω, continue with next step.
NOTE: TAT Probe sensing Element 2 has the same resistance value and can be used as comparator (pins 2 and 5).
- Replace the TAT Probe.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap ADCs.
- Do close out.