03/17/21
Message Overview:
Message Description:
No R-ADC-3 data received at MFD1 and PFD1 receivers.
Possible Causes:
- Right Air Data Computer (ADC 2) (A2)
- Left Adaptive Flight-Display Unit PFD1 (A27)
- Left Adaptive Flight-Display Unit MFD1 (A29)
- Junction Box 3 (JB3)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB3 | AMM 24-63-09-000-802 |
| Installation of the Junction Box JB3 | AMM 24-63-09-400-802 |
| Removal of the Adaptive Flight-Display Unit | AMM 31-61-01-000-801 |
| Installation of the Adaptive Flight-Display Unit | AMM 31-61-01-400-801 |
| Removal of the Air Data Computer | AMM 34-13-01-000-801 |
| Installation of the Air Data Computer | AMM 34-13-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset AIR DATA 2 (CB2-C1) circuit breaker.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do the wiring check of the ARINC 429 databus R-ADC-3 from ADC 2 connector A2P1, through Junction Box 3, to PFD 1 connector A27P2 and MFD 1 connector A29P2. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap ADCs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap PFDs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap MFDs.
- Do close out.