03/17/21
Message Overview:
Message Description:
No R-GP-1 bus data received at ADC2.
Possible Causes:
- Right Air Data Computer (ADC 2) (A2)
- Junction Box 2 (JB2)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Radio Interface Unit (RIU) | AMM 23-51-21-000-801 |
| Installation of the Radio Interface Unit (RIU) | AMM 23-51-21-400-801 |
| Removal of the Junction Box JB2 | AMM 24-63-05-000-803 |
| Installation of the Junction Box JB2 | AMM 24-63-05-400-803 |
| Removal of the Air Data Computer | AMM 34-13-01-000-801 |
| Installation of the Air Data Computer | AMM 34-13-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset AIR DATA 2 (CB2-C1) circuit breaker.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do the wiring check of the ARINC 429 databus R-GP-1 from ADC 2 connector A2P1, through Junction Box 2, to RIU 2 connector A18P1 and to both CDUs (connector A69P1 and connector A68P1). Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap ADCs.
- Do close out.