03/22/21
Message Overview:
Message Description:
R-FMC-6 data absent at R-PFD and R-MFD.
Possible Causes:
- L FMS/L PFD Mode Selection
- R Flight Management Computer (FMC 1) (A4-FMC1)
- Junction Box 2 (JB2)
- Right Adaptive Flight-Display Unit (PFD 2) (A26)
- Right Adaptive Flight-Display Unit (MFD 2) (A28)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-34-0189Pro Line 21 Advanced Avionics Nuisance Messages and FMS-6200 Issues (20501 - 20999)
Forum Articles/Infoservice/Newsletter: None
NOTE: This nuisance message is caused by the FMS-6200 software.
Work Around: Switching to the map function for the Right and / or Left PFD should clear this message.
Quick Links:
| Removal of the Junction Box JB2 | AMM 24-63-05-000-801 |
| Installation of the Junction Box JB2 | AMM 24-63-05-400-801 |
| Removal of the Integrated Avionic Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated Avionic Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Adaptive Flight Display Unit (AFD) | AMM 31-61-01-000-801 |
| Installation of the Adaptive Flight Display Unit (AFD) | AMM 31-61-01-400-801 |
| Removal of the Flight Management Computer (FMC) | AMM 34-61-01-000-801 |
| Installation of the Flight Management Computer (FMC) | AMM 34-61-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Select FMS1 and PPOS Format on L PFD.
- If system check passes, do close out.
- If fault remains, continue with next step.
NOTE: Aircraft has to be WOFW for the message to be seen, and logged, on the MDC.
- Reset R IAPS (CB2-B6) circuit breaker.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do wiring checks of the ARINC 429 data bus R-FMC-6 between IAPS connector A4P103 pins 22 & 24, through Junction Box 2, and L PFD connector A27P2 pins 14 & 15 and L MFD connector A29P2 pins 14 & 15. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
NOTE: An internal short of any LRUs connected to this data bus might cause this failure.
- Swap FMCs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap PFDs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap MFDs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace IAPS Card Cage (ICC).
- Do close out.