Message Description:
R-GPS-3 input to IRS 1 is inactive, while R-GPS-3 input to IRS 2 is reported active.
Possible Causes:
- Internal Reference Unit (IRU) 1 (A233)
- Configuration Connector (J2001)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Inertial Reference Unit (IRU) | AMM 34-45-01-000-801 |
| Installation of the Inertial Reference Unit (IRU) | AMM 34-45-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset IRU 1 (CB1-C2) circuit breaker.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap IRUs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do wiring check of the ARINC 429 data bus R-GPS-3 from IRU 1 connector A233P1 to configuration connector J2000. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Repair/replace configuration connector J2000.
- Do close out.