03/24/21
Message Overview:
Message Description:
TSS data bus (TA/RA-2) is reported absent by the right MFD, while the right IOC does not receive right PFD data.
Possible Causes:
- Adaptive Flight-Display Unit 'A429 Input' (R MFD) (A28)
- Adaptive Flight-Display Unit (R PFD) (A26)
- Junction Box 1 (JB1)
- Traffic/Collision Avoidance System (TCAS) and Traffic Surveillance System (TSS) Transponder (A238)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB1 | AMM 24-63-01-000-802 |
| Installation of the Junction Box JB1 | AMM 24-63-01-400-802 |
| Removal of the Adaptive Flight-Display Unit | AMM 31-61-01-000-801 |
| Installation of the Adaptive Flight-Display Unit | AMM 31-61-01-400-801 |
| Removal of the Traffic/Collision Avoidance System (TCAS) and Surveillance System Transponder Unit (TSS) | AMM 34-43-03-000-801 |
| Installation of the Traffic/Collision Avoidance System (TCAS) and Surveillance System Transponder Unit (TSS) | AMM 34-43-03-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practices - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Confirm all switches on the reversion select panel are selected to NORM.
- Reset R MFD Circuit Breaker CB2-C5 and R PFD Circuit Breaker CB2-C3. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Interchange R MFD (A28) with L MFD (A29). Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Interchange R PFD (A26) with L PFD (A27). Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Do wiring check between R MFD (A28), through JB1, and R PFD (A26) for the following wires:
From: To: Result: Conn. A28P2 - 84 Conn. A26P2 - 84 Conn. A28P2 - 85 Conn. A26P2 - 85 - If the check is not satisfactory, repair defective wiring or replace defective JB1.
- If the check is satisfactory, continue with next step.
- Do wiring check between R MFD (A28), through JB1, and TSS (A238) for the following wires:
From: To: Result: Conn. A28P2 - 84 Conn. A238EP1 - E1 Conn. A28P2 - 85 Conn. A238EP1 - F1 - If the check is not satisfactory, repair defective wiring or replace defective JB1.
- If the check is satisfactory, replace TSS (A238).
- Do close out.