03/25/21
Message Overview:
Message Description:
Right PFD data bus (R-PFD-3) is reported failed by 2 of the following: left MFD, left PFD and right MFD.
Possible Causes:
- Adaptive Flight-Display Unit 'A429 output' (R PFD) (A26)
- Adaptive Flight-Display Unit 'A429 input' (L PFD) (A27)
- Adaptive Flight-Display Unit 'A429 input' R MFD (A28)
- Adaptive Flight-Display Unit 'A429 input' L MFD (A29)
- Junction Box 2 (JB2)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB2 | AMM 24-63-05-000-803 |
| Installation of the Junction Box JB2 | AMM 24-63-05-400-803 |
| Removal of the Adaptive Flight-Display Unit | AMM 31-61-01-000-801 |
| Installation of the Adaptive Flight-Display Unit | AMM 31-61-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset L PFD Circuit Breaker CB1-C3, L MFD Circuit Breaker CB1-C5, R PFD Circuit Breaker CB2-C3 and R MFD Circuit Breaker CB2-C5. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Swap R PFD (A26) with L PFD (A27). Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Do wiring check between R PFD, through JB2, and the 3 others Adaptive Flight-Display Units for the following wires:
From: To: Results: Conn. A26P2 - 94 Conn. A28P2 - 26 Conn. A26P2 - 95 Conn. A28P2 - 27 Conn. A26P2 - 94 Conn. A27P1 - 55 Conn. A26P2 - 95 Conn. A27P1 - 56 Conn. A26P2 - 94 Conn. A29P1 - 55 Conn. A26P2 - 95 Conn. A29P1 - 56 - If the check is not satisfactory, repair defective wiring or replace defective JB2.
- if the check if satisfactory, continue with next step.
- Disconnect L PFD (A27). Is the fault message still present?
- If NO, replace defective L PFD (A27).
- If YES, reconnect L PFD and continue with next step.
- Disconnect R MFD (A28). Is the fault message still present?
- If NO, replace defective R MFD (A28).
- If YES, reconnect R MFD and continue with next step.
- Disconnect L MFD (A29). Is the fault message still present?
- If NO, replace defective L MFD (A29).
- If YES, reconnect L MFD and continue with next step.
- Do close out.