03/25/21
Message Overview:
Message Description:
L-IRS-3 bus data absent at PFD 2 and NOT absent at MFD 2.
Possible Causes:
- Junction Box (JB4)
- Adaptive Flight-Display Unit (PFD) (A26)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB4 | AMM 24-63-13-000-802 |
| Installation of the Junction Box JB4 | AMM 24-63-13-400-802 |
| Removal of the Adaptive Flight-Display Unit | AMM 31-61-01-000-801 |
| Installation of the Adaptive Flight-Display Unit | AMM 31-61-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset R PFD (CB2-C3) and R PFD HTR (CB4-F6) circuit breakers.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap AFDs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do wiring checkof the ARINC 429 data bus L-IRS-3 from PFD 2 connector A26P1 to Junction Box #4 connector JB4CP1 or respective Test Points. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace Junction Box #4.
- Do close out.