03/25/21
Message Overview:
Message Description:
Right FMC data bus (R-FMC-2) is reported absent by the right PFD and the right IOC has not received right MFD data.
Possible Causes:
- Adaptive Flight-Display Unit 'A429 Input' (R PFD) (A26)
- Adaptive Flight-Display Unit 'A429 Input' (R MFD) (A28)
- Junction Box 2 (JB2)
- Right Flight Management Computer (R FMC) (A4-FMC2)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Junction Box JB2 | AMM 24-63-05-000-803 |
| Installation of the Junction Box JB2 | AMM 24-63-05-400-803 |
| Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Adaptive Flight-Display Unit | AMM 31-61-01-000-801 |
| Installation of the Adaptive Flight-Display Unit | AMM 31-61-01-400-801 |
| Removal of the Flight Management Computer (FMC) | AMM 34-61-01-000-801 |
| Installation of the Flight Management Computer (FMC) | AMM 34-61-01-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practices - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Confirm all switches on the reversion select panel are selected to NORM.
- Reset R PFD Circuit Breaker CB2-C3 and R MFD Circuit Breaker CB2-C5. Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Interchange R PFD (A26) with L PFD (A27). Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Interchange R MFD (A28) with L MFD (A29). Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Interchange R FMC (A4-FMC2) with L FMC (A4-FMC1). Is the fault message still present?
- If NO, do close out.
- If YES, continue with next step.
- Do wiring check between R PFD (A26), through JB2, and R MFD (A28) for the following wires:
From: To: Result: Conn. A26P2 - 14 Conn. A28P2 - 14 Conn. A26P2 - 15 Conn. A28P2 - 15 - If the check is not satisfactory, repair defective wiring or replace defective JB2.
- If the check is satisfactory, continue with next step.
- Do wiring check between R PFD (A26), through JB2, and IAPS Card Cage (ICC) (A4) for the following wires:
From: To: Result: Conn. A26P2 - 14 Conn. A4P101 - 26 Conn. A26P2 - 15 Conn. A4P101 - 27 - If the check is not satisfactory, repair defective wiring or replace defective JB2.
- If the check is satisfactory, continue with next step.
- Replace IAPS Card Cage (A4).
- Do close out.