03/31/21
Message Overview:
Message Description:
SVC data is absent at the IOC.
Possible Causes:
- Synthetic Vision Computer (SVC) (A230)
- Input/Output Concentrator Unit 1 (IOC) (A4-IOC1)
- Input/Output Concentrator Unit 2 (IOC) (A4-IOC2)
- Integrated-Avionics Processor System (IAPS) Card Cage (ICC) (A4)
- Video Interface Unit (VIU) (CP32)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/ Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
NOTE: A GPS signal input is required for the SVS image to show on the pilot and the copilot primary flight display (PFD).
Quick Links:
| Removal of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-000-801 |
| Installation of the Integrated-Avionics Processor System (IAPS) Card Cage (ICC) | AMM 31-45-01-400-801 |
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Removal of the Synthetic Vision Computer (SVC) | AMM 34-34-01-000-801 |
| Installation of the Synthetic Vision Computer (SVC) | AMM 34-34-01-400-801 |
| Removal of the Video Interface Unit (VIU) | AMM 34-34-09-000-801 |
| Removal of the Video Interface Unit (VIU) | AMM 34-34-09-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset SVS (CB2-A7) circuit breaker.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Confirm 28 VDC and grounds at SVC connector A230AP1. Repair/replace as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
NOTE: Video Interface Unit (VIU) is sharing the same power source as the SVC and it have to be considered as a possible cause during the 28 VDC troubleshooting.
- Swap IOCs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do wiring check of the ARINC 429 data bus SVC-1 from SVC connector A230AP1 to IAPS Card Cage (ICC) connector A4P1. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace SVC.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace IAPS Card Cage (ICC).
- Do close out.