04/02/21
Message Overview:
Message Description:
TERR-2 (453) bus not received at R-PFD.
Possible Causes:
- Terrain-Avoidance Warning System Computer (TAWS) (A34)
- Right Primary Flight Display (R PFD) (A26)
- Right Multi-Function Display (R MFD) (A28)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Adaptive Flight-Display Unit | AMM 31-61-01-000-801 |
| Installation of the Adaptive Flight-Display Unit | AMM 31-61-01-400-801 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Repair Wiring | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset TAWS (CB2-A6) circuit breaker or push in the TAWS TEST/RESET Switch on the center pedestal.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Do the wiring check of the ARINC 453 data bus TERR-2 between TAWS computer connector A34AP1 to the R PFD connector A26P1. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
NOTE: An internal short of any LRUs connected to this data bus might cause this failure.
- Do the wiring check of the ARINC 453 data bus TERR-2 between R PFD connector A26P1 and R MFD connector A28P1. Repair/replace as required.
- If system check passes, do close out.
- If fault remains, continue with next step.
NOTE: An internal short of any LRUs connected to this data bus might cause this failure.
- Swap PFDs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Swap MFDs.
- If system check passes, do close out.
- If fault remains, continue with next step.
- Replace the TAWS computer.
- Do close out.