Message Overview:
Message Description:
The Bleed Valve 2 is detected failed in closed position. Check valve or position switch or wiring between the valve and the bleed/air condition panel.
Possible Causes:
- Bleed Valve 2 (V4)
- Integrated Air System Controller 2 (IASC) (A56)
- Junction Box (JB2)
- Air Conditioning / Bleed Control Panel (PL17)
- Fire-Detection And Extinguishing Control Unit (FIREX) (A91)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Removal of the Junction Box JB2 | AMM 24-63-05-000-803 |
| Installation of the Junction Box JB2 | AMM 24-63-05-400-803 |
| Removal of the Fire-Detection-and-Extinguishing (FIREX) Control-Unit | AMM 26-11-01-000-801 |
| Installation of the Fire-Detection-and-Extinguishing (FIREX) Control-Unit | AMM 26-11-01-400-801 |
| Operational Test of the Bleed Air System | AMM 36-11-00-710-801 |
| Removal of the Intermediate Pressure Valve | AMM 36-11-05-000-801 |
| Installation of the Intermediate Pressure Valve | AMM 36-11-05-400-801 |
| Removal of the Bleed-Air Control Panel | AMM 36-11-57-000-801 |
| Installation of the Bleed-Air Control Panel | AMM 36-11-57-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Make sure the R BLEED PBA is ON.
- Reset the R BLEED VALVES (V04) circuit breakers CB2-D15.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between the right bleed valve (V4) and the ground. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Manually set the lever of the right bleed valve (V4) to OPEN and CLOSED, then do a continuity check between Pin 4 and Pin 5 of the connector V4J1.
- If there is continuity, go to step 6.
- If there is no continuity, continue with next step.
- Replace the right bleed valve.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do the Operational Test of the Bleed Air System.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between the right bleed valve (V4) and the IASC 2. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap the IASC 2 with the IASC 1.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between the right bleed valve and the Air Cond/Bleed Panel. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check of the Air Cond/Bleed Panel. Repair as required or replace the ON/OFF R BLEED PBA.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between the Air Cond/Bleed Panel and the JB2. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between PIN B2 and B3 of the JB2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace Junction Box #2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between JB2 and the Circuit Breaker CB2-D15. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between JB2 and the FIREX Control Unit. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the FIREX Control Unit.
- Do close out.