04/06/21
Message Overview:
Message Description:
The right bleed pressure on the intermediate pressure stage has been detected below the minimum allowed limit of 15 psig. Check the value of the right bleed valve regulated pressure.
Possible Causes:
- R Bleed Pressure Transducer (MT22)
- Integrated Air System Controller (IASC) 2 (A56)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Integrated Air System (IAS) Controller | AMM 21-31-01-000-801 |
| Installation of the Integrated Air System (IAS) Controller | AMM 21-31-01-400-801 |
| Operational Test of the Bleed Air System | AMM 36-11-00-710-801 |
| Removal of the Bleed Pressure Transducer | AMM 36-11-03-000-801 |
| Installation of the Bleed Pressure Transducer | AMM 36-11-03-400-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Reset the PRESS 2 / TRIM circuit breaker CB2-D14.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do wiring check between the R BLEED PRESSURE SENSOR (MT22) and the IASC 2. Repair as required.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap R BLEED PRESSURE SENSOR (MT22) with the L BLEED PRESSURE SENSOR (MT21).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do the Operational Test of the Bleed Air System.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap IASC 2 with the IASC 1.
- Do Close out.