04/26/21
Message Overview:
Message Name:
GALLEY CONTROL PANEL DISPLAYS DRM LOGO ON EQUIPMENT PAGE
| Identifier: | 441OBS004 |
| Effectivity: | Aircraft 20501 - 20999 |
| System: | nice® HD Cabin Management System |
| Reporting LRU: | Galley Control Panel |
| System Description: | SmartFix Plus 44-00-00, TUG C-ABT207-UG-001 |
| Schematic Diagram: | TUGC-ABT207-UG-001 |
| Wiring Diagram: | SWDM W1002467113 CMS Power Distribution SWDM W1004411113 CMS Network SWDM W1004411133 CMS Control SWDM W1004421113 Personal Control System |
Message Description:
Galley Control Panel (GCP) displays Digital Rights Management (DRM)-logo on CMS equipment page, upper right corner.
Possible Causes:
- Digital Rights Management (DRM) keys of one or more LRUs of the nice® HD CMS/IFE system are inaccurate/missing:
- Missing/Incomplete DRM Update Procedure
- Missing/Incomplete LRU Update (e.g. after LRU exchange)
- Wrong Configuration Software DataBase (CSDB) Used
Required Conditions:
- Ensure CMS/IFE system is booted up completely (power on and wait for about 5 minutes to ensure proper system status reporting).
- On Galley Control Panel (GCP) navigate to CMS equipment page, select item "system software" and ensure the aircraft MSN is contained in "current p/n" (e.g. for Challenger C350, MSN 20613: p/n SCDC350-20613-A or p/n SCDC3-20613-04A).NOTE: If p/n is incorrect, contact the Bombardier CRC for further instructions.
- Check if special requirements apply and ensure necessary tools are available in reference to Software Load Procedure for nice® HD on CL350 (C-ABR142-UG-001), chapter 3.; e.g.
- DRM update requires internet connection.
- EDID update requires external HDMI source.
- Windows update, requires USB memory stick with CSDB and system software.
- nice®view terrain update requires Terrain Hard Disk Drive p/n FTS0407NVT004 or newer.
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- SB 350-44-001 - MODIFICATION - Cabin Management System (CMS) - System Configuration Database Software Update
Forum Articles/Infoservice/Newsletter:
- EIU3009-SIL44-0001 - Ethernet Interface Unit: Increased time required for device update
- EIU Replacement Checklist - Checklist for EIU3009-001-001 replacement
NOTE: To check for release of updated System Software - Configuration Server Database (CSDB), please refer to Bombardier CIC webpage technical library, Service Bulletins for Challenger 350.
NOTE: Respective Lufthansa Technik "Engineering Bulletin Component" (EBC) documents are provided on this page as well.
NOTE: More details in the nice® HD CMS/IFE system are available within the Lufthansa Technik document C-ABT207-UG-001, CL350 nice® HD Technical User Guide (TUG).
Quick Links:
| Lufthansa Technik Technical User Guide (TUG) | CL350 nice® HDC-ABT207-UG-001 |
| Lufthansa Technik Software Load Procedure (SLP) | CL350 nice® HDC-ABR142-UG-001 |
Troubleshooting Recommendations:
In reference to Software Load Procedure for nice® HD on CL350 (C-ABR142-UG-001) chapter 3:
- Perform "DRM update".
- Ensure DRM logo changes to green color.
NOTE: If color stays amber, a "special tool" for DRM update is missing. (No connection to DRM Server, most likely due to insufficient internet connection quality). The update will fail.
- Ensure DRM logo changes to green color.
- Perform an update of the affected LRU(s).
- Do close out.