Message Overview:
Message Name:
PASSENGER CONTROL UNIT DISPLAYS "TERRAIN UPDATE REQUIRED"
| Identifier: | 441OBS017 |
| Effectivity: | Aircraft 20501 - 20999 |
| System: | nice® HD Cabin Management System |
| Associated CAS: | None |
| Reporting LRU: | PSM2410-00X-001 |
| System Description: | SmartFix Plus 44-00-00, TUG C-ABT207-UG-001 |
| Schematic Diagram: | TUGC-ABT207-UG-001 |
| Wiring Diagram: | SWDM W1002467113 CMS Power Distribution SWDM W1004411113 CMS Network SWDM W1004411133 CMS Control SWDM W1004421113 Personal Control System |
Message Description:
When niceview™ (moving map system) is selected in one or more overhead or passenger displays, the message "Terrain update required" is shown.
Possible Causes:
- No Terrain Data Available
- Faulty Terrain Data
- Incomplete Update/Download of Terrain Data
Required Conditions:
- Ensure nice® HD CMS/IFE system is booted up completely (power on and wait for about 5 minutes to ensure proper system status reporting).
- On Galley Control Panel (GCP) navigate to home, cms equipment page, item "system software" and ensure the aircraft MSN is contained in "current p/n" (e.g. for Challenger C350, MSN 20613: p/n SCDC350-20613-A or p/n SCDC3-20613-04A).
Note: If p/n is incorrect, contact CRC for further instructions. - Tools required: see Software Load Procedure for nice® HD on CL350 (C-ABR142-UG-001), section TOOLS FOR NICEVIEW™ TERRAIN DATABASE UPDATE
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- SB 350-44-001 - MODIFICATION - Cabin Management System (CMS) - System Configuration Database Software Update
Forum Articles/Infoservice/Newsletter:
- EIU3009-SIL44-0001 - Ethernet Interface Unit: Increased time required for device update
- EIU Replacement Checklist - Checklist for EIU3009-001-001 replacement
More details in the nice® HD CMS/IFE system are available within the Lufthansa Technik document C-ABT207-UG-001, CL350 nice® HD Technical User Guide (TUG).
Quick Links:
| Lufthansa Technik Technical User Guide (TUG) | CL350 nice® HDC-ABT207-UG-001 |
| Lufthansa Technik Software Load Procedure (SLP) | CL350 nice® HDC-ABR142-UG-001 |
Troubleshooting Recommendations:
- Perform "Software Load Procedure for nice® HD on CL350" (C-ABR142-UG-001), section "Perform niceview™ Terrain Database Update".
Requirements after Job Completion:
Ensure the system status is reported as "ready" after a reboot (allow system to run for about 5 minutes to stabilize display of system state).