07/01/24
Message Overview:
Message Description:
The Left Generator Control Unit (LGCU) has failed.
Possible Causes:
- Left Generator Control Unit (LGCU) (PCB5)
- Left Generator Power Module (LGPM) (PCB7)
- Left Generator (LGEN) (G1)
- Left DC Power Center (LDCPC) (A35)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-24-0013 - Loss of Normal Electrical Power
- AW300-24-0038 - Nuisance "ELECTRICAL FAULT" CAS Message Upon Engine or APU Shut Down.
Forum Articles/Infoservice/Newsletter: None
NOTES:
- If all or any combination of the following MDC faults are posted at the same time, troubleshoot the MDC Fault B3-006657 first.
B3-007087 - FAULT [L GEN GCU]
B3-006292 - FAULT [APU GEN GCU]
B3-006657 - DPMS2/RPROT/WIRING FAULT [DIFF PROT SNSR - If the MDC is reporting multiple GEN GCU fault messages simultaneously, accompanied by a Proximity Sensing Electronics Unit (PSEU) failure, most likely B3-007551 - PSEU SYSTEM FAILURE or B3-007550 - PSEU OFF/NO OUTPUT, the ATA 32 fault(s) must be addressed first.
- For troubleshooting purposes you may refer to the Generators Windings Values table.
Quick Links:
| Standard Aircraft Configuration for Maintenance | AMM 12-00-00-867-803 |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 |
| Removal of the Main Generator | AMM 24-31-05-000-801 |
| Installation of the Main Generator | AMM 24-31-05-400-801 |
| Operational Test of the Main Generator | AMM 24-31-05-710-801 |
| Removal of the Generator Control Unit (GCU) - Primary | AMM 24-31-13-000-801 |
| Installation of the Generator Control Unit (GCU) - primary | AMM 24-31-13-400-801 |
| Removal of the Generator Power Module | AMM 24-31-21-000-801 |
| Installation of the Generator Power Module | AMM 24-31-21-400-801 |
| Removal of the DC Power Center (DCPC) | AMM 24-61-01-000-801 |
| Installation of the DC Power Center (DCPC) | AMM 24-61-01-400-801 |
| Functional Test of the DC Power Center (DCPC) | AMM 24-61-01-720-801 |
| Standard Practices - Replace Wiring | SPM20-12-00-02-01 |
| Standard Practices - Wire Repair | SPM20-12-10-02-01 |
Troubleshooting Recommendations:
- Swap the Left Generator Control Unit (PCB5) with the Right Generator Control Unit (PCB6). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective Generator Control Unit.
- Swap the Left Generator Power Module (PCB7) with the Right Generator Power Module (PCB8). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective Generator Power Module.
- Do wiring check of the following wires:
From To Results L GEN conn. G1P1 - pin A L DCPC conn. A35P1 - pin F L GEN conn. G1P1 - pin B L DCPC conn. A35P1 - pin G L GEN conn. G1P1 - pin G L DCPC conn. A35P1 - pin AA L GEN conn. G1P1 - pin D L DCPC conn. A35P1 - pin H L GEN conn. G1P1 - pin F L DCPC conn. A35P1 - pin h L GEN conn. G1P1 - pin E L DCPC conn. A35P1 - pin J L GEN conn. G1P1 - pin L L DCPC conn. A35P1 - pin JJ L GEN conn. G1P1 - pin M L DCPC conn. A35P1 - pin z L GEN conn. G1P1 - pin H L DCPC conn. A35P1 - pin D L GEN conn. G1P1 - pin J L DCPC conn. A35P1 - pin d L GEN conn. G1P1 - pin K L DCPC conn. A35P1 - pin E - If wiring check is satisfying, continue with next step.
- If wiring check is not satisfying, repair the defective wire.
- Swap the Left Generator (G1) with the Right Generator (G2). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective Generator.
- Replace Left DC Power Center (A35).
- Do close out.