background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults by MDCBy Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

05/06/21

Message Overview:

Message Name:

MCS3 OR LPROT PCB FAULT

Message Code:

B3-007148

Associated CAS:

ELECTRICAL FAULT
(Caution)

ELECTRICAL FAULT
(Advisory)

Reporting LRU: LBAT CUR SNSR3
System Description: 24-32-00
24-61-00
Schematic Diagram: 24-32-00
24-61-00
Wiring Diagram: 24-32-01
24-61-01

Message Description:

A failure with the Left Battery Monitoring Sensor or the Left Protection PCB has been reported by the Left DC Power Center.

Possible Causes:

  • Left Battery Sensor (MCS3) (MPE073)
  • Left DC Power-Center Protection (LPROT) (PCB1)
  • Left DC Power Center (LDCPC) (A35)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the DC Power Center (DCPC) AMM 24-61-01-000-801
Installation of the DC Power Center (DCPC) AMM 24-61-01-400-801
Functional Test of the DC Power Center (DCPC) AMM 24-61-01-720-801
Removal of the Battery Sensor AMM 24-61-45-000-801
Installation of the Battery Sensor AMM 24-61-45-400-801
Removal of the DC Power-Center Protection AMM 24-61-77-000-801
Installation of the DC Power-Center Protection AMM 24-61-77-400-801
Wiring - Maintenance Practices - ALL SPM 20-12-00-02
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02

Troubleshooting Recommendations:

  1. Disconnect the Left Battery Sensor (MPE073) connector located in the Left DC Power Center (A35). Do visual inspection of the connector and associated wiring for any loose pins and/or damaged wire.

    1. If inspection is satisfying, continue with next step.
    2. If inspection is not satisfying, go to step 4.

  2. Interchange Left Battery Sensor (MPE073) with the Right Battery Sensor (MPE074). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective Battery Sensor.

  3. Interchange the Left DC Power-Center Protection (PCB1) with the Right Power-Center Protection (PCB2). Is the fault message still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective DC Power-Center Protection.

  4. Replace Left DC Power-Center (A35).
  5. Do close out.