Message Overview:
Message Name:
FAULT
Message Code:
B3-007767
Associated CAS:
| Reporting LRU: | RIGHT GENERATOR |
| System Description: | 24-31-00 - Primary DC Power System 24-61-00 - DC Power Center (DCPC) |
| Schematic Diagram: | SSM 24-31-00-101 - Primary DC-Power System SSM 24-61-00-101 - DC Power Center (DCPC) System |
| Wiring Diagram: | 24-31-07 - Main Generator (Right) - ALL 24-31-15 - Generator Control Unit (GCU) Right - ALL 24-61-03 - DC Power Center (DCPC) Right - 20501 TO 20960 |
Message Description:
The Right Generator (RGEN) has failed.
Possible Causes:
- Right Generator (RGEN) (G2)
- Right Generator Control Unit (RGCU) (PCB6)
- Right Generator Power Module (RGPM) (PCB8)
- Right DC Power Center (RDCPC) (A36)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-24-0013 - Loss of Normal Electrical Power
- AW300-24-0038 - Nuisance "ELECTRICAL FAULT" CAS Message Upon Engine or APU Shut Down.
- AW300-24-0115 - Introduction of Improved Generator P/N A3579-102
- AW300-24-0132 - Power Module (PMOD) P/N R3608-011 - Generator Failures at High Engine Speed
- AW300-24-0137 - Y06 Electrical System Upgrade
- AW300-24-0162 - Service Bulletin 100-24-20 - DC Power Center (DCPC) System - Inspection and Replacement of Internal Fuses in the L/H and R/H DC Power Center (DCPC)
Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None
Flight Operation Notifications Manual (FONM): None
NOTES:
Quick Links:
| General Setup for Maintenance | |
|---|---|
| Standard Aircraft Configuration for Maintenance | AMM 12-00-00-867-803 |
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 |
| Remove Electrical Power from the Aircraft | AMM 24-00-00-861-802 |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 |
| Electrostatic Discharge Safety Precautions | AMM 24-00-00-910-802 |
| Maintenance Tasks | |
| Removal of the Main Generator | AMM 24-31-05-000-801 |
| Installation of the Main Generator | AMM 24-31-05-400-801 |
| Removal of the Generator Control Unit (GCU) - Primary | AMM 24-31-13-000-801 |
| Installation of the Generator Control Unit (GCU) - primary | AMM 24-31-13-400-801 |
| Removal of the Generator Power Module | AMM 24-31-21-000-801 |
| Installation of the Generator Power Module | AMM 24-31-21-400-801 |
| Removal of the DC Power Center (DCPC) | AMM 24-61-01-000-801 |
| Installation of the DC Power Center (DCPC) | AMM 24-61-01-400-801 |
Troubleshooting Recommendations:
- Inspect the Generator Cooling Inlet and Outlet on the engine cowling for obstruction or debris.
- Verify that the Generator electrical connections are secured and in good condition.
- Spin the Right Generator (G2) shaft by hand through the opening of the cooling ports. Does it spin freely?
- If YES (the shaft is sheared), replace the defective Generator.
- If NO (some friction could be felt), continues with next step.
- Do wiring check of the following wires:
From To Results R GEN conn. G2P1 - pin A R DCPC conn. A36P1 - pin F R GEN conn. G2P1 - pin B R DCPC conn. A36P1 - pin G R GEN conn. G2P1 - pin G R DCPC conn. A36P1 - pin AA R GEN conn. G2P1 - pin D R DCPC conn. A36P1 - pin H R GEN conn. G2P1 - pin F R DCPC conn. A36P1 - pin h R GEN conn. G2P1 - pin E R DCPC conn. A36P1 - pin J R GEN conn. G2P1 - pin L R DCPC conn. A36P1 - pin JJ R GEN conn. G2P1 - pin M R DCPC conn. A36P1 - pin z R GEN conn. G2P1 - pin H R DCPC conn. A36P1 - pin D R GEN conn. G2P1 - pin J R DCPC conn. A36P1 - pin d R GEN conn. G2P1 - pin K R DCPC conn. A36P1 - pin E - If wiring check is satisfying, continue with next step.
- If wiring check is not satisfying, repair the defective wire.
- Interchange the Right Generator (G2) with the Left Generator (G1). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective Generator.
- Interchange the Right Generator Control Unit (PCB6) with the Left Generator Control Unit (PCB5). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective Generator Control Unit.
- Interchange the Right Generator Power Module (PCB8) with the Left Generator Power Module (PCB7). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective Generator Power Module.
- Replace Right DC Power Center (A36).
- Do close out.