Message Overview:
Message Description:
No R-DCPC output bus data to RDC.
Possible Causes:
- Right DC Power-Center Protection (RPROT) (PCB2)
- Remote Data Concentrator (RDC) (A13)
- Right Power Center (DCPC) (A36)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-01-000-801 |
| Installation of the DC Power Center (DCPC) | AMM 24-61-01-400-801 |
| Functional Test of the DC Power Center (DCPC) | AMM 24-61-01-720-801 |
| Removal of the DC Power-Center Protection | AMM 24-61-77-000-801 |
| Installation of the DC Power-Center Protection | AMM 24-61-77-400-801 |
| Removal of the Remote Data Concentrator (RDC) | AMM 31-41-05-000-802 |
| Installation of the Remote Data Concentrator (RDC) | AMM 31-41-05-400-802 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
Troubleshooting Recommendations:
- Swap the Right DC Power-Center Protection (PCB2) with the Left DC Power-Center Protection (PCB1). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective DC Power-Center Protection.
- Do wiring check of the following wires:
From To Results RDC conn. A13EP1 - pin 2A R DCPC conn. A36P2 - pin L RDC conn. A13EP1 - pin 2B R DCPC conn. A36P2 - pin M - If wiring check is satisfying, continue with next step.
- If wiring check is not satisfying, repair the defective wire.
- Replace Remote Data Concentrator (A13). Is the fault message still present?
- If YES, continue with next step.
- If NO, replace the defective Remote Data Concentrator.
- Replace Right DC Power Center (A36).
- Do close out.