01/24/24
Message Overview:
Message Name:
NO R-GP-5 BUS INPUT
Message Code:
B3-006685
Associated CAS:
| Reporting LRU: | FLAP CTRL UNIT |
| System Description: | 27-51-00 - Control And Indication System (Flap) |
| Schematic Diagram: | SSM 27-52-00-101 - Flap System |
| Wiring Diagram: | WM 27-52-33-1_001 - Sheet 1 - Flap Power Unit (FPU) - ALL WM 31-45-07-1_001 - Sheet 1 - Integrated Avionics Processor System (R-GP-5) - [20501 to 20886, 20888 to 20890, 20896 to 20898] WM 31-45-07-2_001 - Sheet 1 - Integrated Avionics Processor System (R-GP-5) - [20887, 20891 to 20895, 20899 AND SUBS] |
Message Description:
Flap Control Unit (FCU) reports no data from R-GP-5 bus. Check ARINC output from Right Input/Output Concentrator (IOC).
Possible Causes:
- Integrated Avionics Processor System (IAPS) Card Cage (ICC) (A4)/Right Input-Output Concentrator (IOC)
- Flap Control Unit (FCU) (A124)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW300-27-0058 - Flap Control Unit - CAS Messages Reset procedure (20003 to 20999)
Forum Articles/Infoservice/Newsletter: None
NOTE:
- The IOC is a card in the IAPS Card Cage.
Quick Links:
| Removal of the Flap Control Unit (FCU) | AMM 27-51-05-000-801 |
| Installation of the Flap Control Unit (FCU) | AMM 27-51-05-400-801 |
| Operational Test of the Flap Control Unit (FCU) | AMM 27-51-05-710-801 |
| Removal of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-000-801 |
| Installation of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-400-801 |
| Operational Test of the Input/Output Concentrator Unit (IOC) | AMM 31-45-05-710-801 |
| Wiring - Maintenance Practices - ALL | SPM 20-12-00-02 |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 |
| Electrical Connectors - Maintenance Practice - ALL | SPM 20-20-00-02 |
Troubleshooting Recommendations:
- Reset the following circuit breakers:
- If system checks are good, do close out.
- If fault remains, continue with next step.
FLAP R IND CB2-B12 FLAP L IND CB1-B13 FLAP CTRL CB1-B14 - Reset the FCU by pressing the FCU reset button on the MAINTENANCE TEST control-panel. If unable to reset, engage the Alternate Flaps button with the left hydraulic system pressurized and attempt another reset using the Flap Reset switch on the left galley.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Interchange the IOCs.
- If fault follow, replace defective IOC. Do system checks and close out.
- If fault remains on left side, continue with next step.
- Perform wiring check on R-GP-5 bus integrity between R IOC and FCU per AWM.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace FCU (A124).
- If system checks are good, continue with next step.
- Do close out.