03/16/21
Message Overview:
Message Description:
The right inboard brake control valve resistance is out of limit (open/short).
Possible Causes:
- Brake Control Unit (BCU) (A67)
- Right Brake Control Valve (BCV) (MPE23)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Brake Control Unit | AMM 32-43-01-000-801 |
| Installation of the Brake Control Unit | AMM 32-43-01-400-801 |
| Removal of the Brake Control Valve | AMM 32-43-09-000-801 |
| Installation of the Brake Control Valve | AMM 32-43-09-400-801 |
| Data Download from the Maintenance Diagnostic Computer (MDC) | AMM 45-45-01-970-802 |
| Standard Practices - Replace Wiring | SPM 20-12-00-02 |
| Standard Practices - Electrical Wiring - Continuity Test - Adjustment/Test | SPM 20-12-01-05 |
| Standard Practices - Wire Repair | SPM 20-12-10-02 |
Troubleshooting Recommendations:
NOTE: If assistance is required, send a download of the BCU NVM to Bombardier CRC for analysis.
- Inspect inboard BCV connector and wiring.
- Repair as required.
- If no fault found, go to next step.
- Swap inboard and outboard BCV.
- If problem follows, replace BCV.
- If problem does not follow, go to next step.
- Carry out a wiring check per the following table:
Connector - BCU Pin Connector - INBD BCV Pin A67P2 78 MPE23P1 5 A67P2 77 MPE23P1 4 - Repair wiring as required.
- If wiring is found serviceable, go to next step.
- Replace BCU.